116 research outputs found

    Local Delivery Versus Intracoronary Infusion of Abciximab in Patients With Acute Coronary Syndromes

    Get PDF
    ObjectivesWe investigated whether local abciximab delivery to the site of intracoronary thrombus is more effective than intracoronary bolus infusion in patients with acute coronary syndromes (ACS) undergoing percutaneous coronary intervention and downstream clopidogrel administration.BackgroundThe intracoronary route of administration does not allow an optimal contact between the plaque components and abciximab, which is rapidly washed out by the coronary flow.MethodsA total of 50 patients with ACS and a significant lesion in the culprit artery indicative of local thrombosis were randomly assigned to receive local intracoronary delivery of abciximab through a dedicated perfusion catheter or intracoronary infusion through the guiding catheter. The primary end point was the change in thrombus score after angioplasty by optical coherence tomography.ResultsAfter the intervention, the mean percentage change of the thrombus score was significantly higher among patients of the local delivery group compared with those of the intracoronary infusion group (33.8% vs. 3.9%, p = 0.002). Post-procedural corrected Thrombolysis in Myocardial Infarction frame count was shorter in the local delivery group compared with the intracoronary infusion group (15.3 ± 10.2 vs. 21.1 ± 9.9, p = 0.049). Procedure-related myocardial infarction was observed in 10% and 43% of patients in the local delivery and intracoronary infusion groups, respectively (p = 0.018). At 1 year, MACE were observed in 5.9% and 27.2% of patients in the local delivery and intracoronary infusion groups, respectively (p = 0.046).ConclusionsLocal intracoronary delivery of abciximab by means of a dedicated perfusion catheter reduces thrombus burden with the potential to improve coronary microcirculation

    First-in-Man 1-Year Clinical Outcomes of the Catania Coronary Stent System With Nanothin Polyzene-F in De Novo Native Coronary Artery Lesions The ATLANTA (Assessment of The LAtest Non-Thrombogenic Angioplasty stent) Trial

    Get PDF
    ObjectivesThis study sought to assess safety and efficacy of implantation of the Catania Coronary Stent System with Nanothin Polyzene-F (CeloNova BioSciences, Newnan, Georgia) in human coronary arteries with clinical data and comprehensive intracoronary imaging.BackgroundNovel approaches to modify stents (e.g., bioactive agents, coatings) have been developed to address the limitations of bare-metal and drug-eluting stents (e.g., restenosis, target lesion revascularization [TLR], late thrombosis).MethodsThis first-in-man study using the Catania stent is a prospective, single center, nonrandomized, single-arm study of 55 patients with symptomatic ischemic heart disease with de novo, obstructive lesions of native coronary arteries.ResultsAcute angiographic success was 100%. A core laboratory analyzed quantitative coronary angiography and intravascular ultrasound data immediately after stenting and at 6-month follow-up. Late lumen loss was 0.60 ± 0.48 mm and the percent neointimal hyperplasia volume was 27.9 ± 16.1%. In 15 of 55 randomly selected patients, 1,904 cross-sections (19,028 struts) were analyzed at 6 months by optical coherence tomography. Overall, 99.5% of struts were covered. Only 29 of 19,028 struts (0.15%) were malapposed. Binary angiographic restenosis was 6.8%. No death, myocardial infarction, or Academic Research Consortium–defined stent thrombosis was observed at 12 months. The incidence of TLR at 12 months was clinically driven TLR 3.6% (2 of 55) and nonclinically driven TLR 7.3% (4 of 55).ConclusionsThis first-in-man showed an excellent early and mid-term safety profile and high-level efficacy of the new Catania stent in the treatment of de novo coronary lesions in a fairly complex population. Polyzene-F coated stents may be an alternative to both bare-metal and drug-eluting stents with reduced late loss, restenosis, and the TLR without long-term dual antiplatelet therapy

    Percutaneous mitral valve repair with the MitraClip system: acute results from a real world setting

    Get PDF
    This study sought to evaluate the feasibility and early outcomes of a percutaneous edge-to-edge repair approach for mitral valve regurgitation with the MitraClip((R)) system (Evalve, Inc., Menlo Park, CA, USA).Patients were selected for the procedure based on the consensus of a multidisciplinary team. The primary efficacy endpoint was acute device success defined as clip placement with reduction of mitral regurgitation to < 2+. The primary acute safety endpoint was 30-day freedom from major adverse events, defined as the composite of death, myocardial infarction, non-elective cardiac surgery for adverse events, renal failure, transfusion of > 2 units of blood, ventilation for > 48 h, deep wound infection, septicaemia, and new onset of atrial fibrillation. Thirty-one patients (median age 71, male 81%) were treated between August 2008 and July 2009. Eighteen patients (58%) presented with functional disease and 13 patients (42%) presented with organic degenerative disease. A clip was successfully implanted in 19 patients (61%) and two clips in 12 patients (39%). The median device implantation time was 80 min. At 30 days, there was an intra-procedural cardiac tamponade and a non-cardiac death, resulting in a primary safety endpoint of 93.6% [95% confidence interval (CI) 77.2-98.9]. Acute device success was observed in 96.8% of patients (95% CI 81.5-99.8). Compared with baseline, left ventricular diameters, diastolic left ventricular volume, diastolic annular septal-lateral dimension, and mitral valve area significantly diminished at 30 days.Our initial results with the MitraClip device in a very small number of patients indicate that percutaneous edge-to-edge mitral valve repair is feasible and may be accomplished with favourable short-term safety and efficacy results

    Future Boundary Conditions in De Sitter Space

    Get PDF
    We consider asymptotically future de Sitter spacetimes endowed with an eternal observatory. In the conventional descriptions, the conformal metric at the future boundary I^+ is deformed by the flux of gravitational radiation. We however impose an unconventional future "Dirichlet" boundary condition requiring that the conformal metric is flat everywhere except at the conformal point where the observatory arrives at I^+. This boundary condition violates conventional causality, but we argue the causality violations cannot be detected by any experiment in the observatory. We show that the bulk-to-bulk two-point functions obeying this future boundary condition are not realizable as operator correlation functions in any de Sitter invariant vacuum, but they do agree with those obtained by double analytic continuation from anti-de Sitter space.Comment: 16 page

    Cardiovascular magnetic resonance for the assessment of patients undergoing transcatheter aortic valve implantation: a pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Before trans-catheter aortic valve implantation (TAVI), assessment of cardiac function and accurate measurement of the aortic root are key to determine the correct size and type of the prosthesis. The aim of this study was to compare cardiovascular magnetic resonance (CMR) and trans-thoracic echocardiography (TTE) for the assessment of aortic valve measurements and left ventricular function in high-risk elderly patients submitted to TAVI.</p> <p>Methods</p> <p>Consecutive patients with severe aortic stenosis and contraindications for surgical aortic valve replacement were screened from April 2009 to January 2011 and imaged with TTE and CMR.</p> <p>Results</p> <p>Patients who underwent both TTE and CMR (n = 49) had a mean age of 80.8 ± 4.8 years and a mean logistic EuroSCORE of 14.9 ± 9.3%. There was a good correlation between TTE and CMR in terms of annulus size (R<sup>2 </sup>= 0.48, p < 0.001), left ventricular outflow tract (LVOT) diameter (R<sup>2 </sup>= 0.62, p < 0.001) and left ventricular ejection fraction (LVEF) (R<sup>2 </sup>= 0.47, p < 0.001) and a moderate correlation in terms of aortic valve area (AVA) (R<sup>2 </sup>= 0.24, p < 0.001). CMR generally tended to report larger values than TTE for all measurements. The Bland-Altman test indicated that the 95% limits of agreement between TTE and CMR ranged from -5.6 mm to + 1.0 mm for annulus size, from -0.45 mm to + 0.25 mm for LVOT, from -0.45 mm<sup>2 </sup>to + 0.25 mm<sup>2 </sup>for AVA and from -29.2% to 13.2% for LVEF.</p> <p>Conclusions</p> <p>In elderly patients candidates to TAVI, CMR represents a viable complement to transthoracic echocardiography.</p

    Relationship between coronary plaque morphology of the left anterior descending artery and 12 months clinical outcome: the CLIMA study

    Get PDF
    Abstract Aims The CLIMA study, on the relationship between coronary plaque morphology of the left anterior descending artery and twelve months clinical outcome, was designed to explore the predictive value of multiple high-risk plaque features in the same coronary lesion [minimum lumen area (MLA), fibrous cap thickness (FCT), lipid arc circumferential extension, and presence of optical coherence tomography (OCT)-defined macrophages] as detected by OCT. Composite of cardiac death and target segment myocardial infarction was the primary clinical endpoint. Methods and results From January 2013 to December 2016, 1003 patients undergoing OCT evaluation of the untreated proximal left anterior descending coronary artery in the context of clinically indicated coronary angiogram were prospectively enrolled at 11 independent centres (clinicaltrial.gov identifier NCT02883088). At 1-year, the primary clinical endpoint was observed in 37 patients (3.7%). In a total of 1776 lipid plaques, presence of MLA 180° (HR 2.4, 95% CI 1.2–4.8), and OCT-defined macrophages (HR 2.7, 95% CI 1.2–6.1) were all associated with increased risk of the primary endpoint. The pre-specified combination of plaque features (simultaneous presence of the four OCT criteria in the same plaque) was observed in 18.9% of patients experiencing the primary endpoint and was an independent predictor of events (HR 7.54, 95% CI 3.1–18.6). Conclusion The simultaneous presence of four high-risk OCT plaque features was found to be associated with a higher risk of major coronary events

    Characteristic Evolution and Matching

    Get PDF
    I review the development of numerical evolution codes for general relativity based upon the characteristic initial value problem. Progress in characteristic evolution is traced from the early stage of 1D feasibility studies to 2D axisymmetric codes that accurately simulate the oscillations and gravitational collapse of relativistic stars and to current 3D codes that provide pieces of a binary black hole spacetime. Cauchy codes have now been successful at simulating all aspects of the binary black hole problem inside an artificially constructed outer boundary. A prime application of characteristic evolution is to extend such simulations to null infinity where the waveform from the binary inspiral and merger can be unambiguously computed. This has now been accomplished by Cauchy-characteristic extraction, where data for the characteristic evolution is supplied by Cauchy data on an extraction worldtube inside the artificial outer boundary. The ultimate application of characteristic evolution is to eliminate the role of this outer boundary by constructing a global solution via Cauchy-characteristic matching. Progress in this direction is discussed.Comment: New version to appear in Living Reviews 2012. arXiv admin note: updated version of arXiv:gr-qc/050809

    Clinical Outcomes With a Repositionable Self-Expanding Transcatheter Aortic Valve Prosthesis: The International FORWARD Study

    Get PDF
    Background Clinical outcomes in large patient populations from real-world clinical practice with a next-generation self-expanding transcatheter aortic valve are lacking. Objectives This study sought to document the clinical and device performance outcomes of transcatheter aortic valve replacement (TAVR) with a next-generation, self-expanding transcatheter heart valve (THV) system in patients with severe symptomatic aortic stenosis (AS) in routine clinical practice. Methods The FORWARD (CoreValve Evolut R FORWARD) study is a prospective, single-arm, multinational, multicenter, observational study. An independent clinical events committee adjudicated safety endpoints based on Valve Academic Research Consortium-2 definitions. An independent echocardiographic core laboratory evaluated all echocardiograms. From January 2016 to December 2016, TAVR with the next-generation self-expanding THV was attempted in 1,038 patients with symptomatic, severe AS at 53 centers on 4 continents. Results Mean age was 81.8 ± 6.2 years, 64.9% were women, the mean Society of Thoracic Surgeons Predicted Risk of Mortality was 5.5 ± 4.5%, and 33.9% of patients were deemed frail. The repositioning feature of the THV was applied in 25.8% of patients. A single valve was implanted in the proper anatomic location in 98.9% of patients. The mean aortic valve gradient was 8.5 ± 5.6 mm Hg, and moderate or severe aortic regurgitation was 1.9% at discharge. All-cause mortality was 1.9%, and disabling stroke occurred in 1.8% at 30 days. The expected-to-observed early surgical mortality ratio was 0.35. A pacemaker was implanted in 17.5% of patients. Conclusions TAVR using the next-generation THV is clinically safe and effective for treating older patients with severe AS at increased operative risk. (CoreValve Evolut R FORWARD Study [FORWARD]; NCT02592369
    corecore